Harsh environment Emergency Lighting Inverter
Keep the lights ββONββ when you need them the most.
0.35, 0.525, 0.7, 0.875, 1.05, 1.4, 2.0, 2.4, 2.6, 3.0, 3.4, 3.8, 4.2, 4.7, 5.25, 7, 8, 10, 12, 14, 18, and 21KW
120, 208, 240, 277, or 480VAC
120, 277, 480, 120/240 or 120/277VAC
The Fortress Harsh 1 maintains efficient AC Emergency Power
to operate all emergency lighting fixtures at βfull-lightβ output,
providing superior dependability and security to
commercial/industrial environments in an outdoor environment.
β’ 0.075 KW β 21 KW (or 75 Watts β 21,000 Watts) single phase
output unit uses the latest DSP/PWM technology to provide
the most advanced performance and reliability features
β’ 120V, 208V, 240V, 277V, 480V, 120/240 or 120/277VAC
True βon-lineβ design is β₯92% efficient at 100% linear load
β’ Provides overload, surge and undercurrent protection using
DSP/PWM technology and DSPM Watchdog Software to
protect system performance and reliability
β’ Surge protection against load surges as defined in
ANSI/IEEE C62.45 category A and B
β’ Provides overload, surge and undercurrent protection using
DSP/PWM technology and DSPM Watchdog Software to
protect system performance and reliability
β’ Surge protection against load surges as defined in
ANSI/IEEE C62.45 category A and B
β’ Modular design enables flexible installation
β’ Forced air cooling for maximum reliability
β’ Systems up to 10 KW are self contained; larger systems
require external battery cabinet(s)
β’ Modular design and small footprint allow easy installation in
an outdoor environment
β’ Phone assisted factory start-up standard for all systems
β’ Extended warranty available
Β β’ DSPM offers numerous UL924 optional devices to meet unusual
or difficult application parameters
β’ ECM β Environmental Circuit Module allows fixtures and lamps on
the emergency circuit(s) to be operated by normal switching
and/or dimming devices in NON-emergency conditions
β’ Dimming Panel Interface allows use with emergency lights
controlled by common dimmer panel
β’ 1-Year full warranty on system electronics
β’ System 1-year on-site warranty labor with
DSPM phone assisted start-up
β’ 5-Year powertrain warranty
β’ Maintenance contracts available
When the utility is present the load is connected to the Utility (Input Source), Fortress Harsh Family takes the utility power and connects it to the load.
In the case of a power outage, Fortress Harsh systems will convert the power on batteries to the required output power for the load.
Choose the bold face catalog nomenclature that best suites your needs.
Write them on the appropriate line. Order accessories as separate catalog number.
Example:
FTH1 – 8.0 – 120/277 – ECM277/3 OCB/277/3/20/1 – 180
Description of example:
(8.0 KW, 120 Voltage In, 277 Voltage Out, 3 277V Environmental Control Modules, 3 Output 277 Voltage Circuit Breakers at 20amps, 2 pole, 180 minute run time)